Categories
Categories
Brands
Brands
- Home
- Plenum Cable
- RG6 PLENUM COMMSCOPE 2276V VIDEO CABLE RG 6 1000 FEET
RG6 PLENUM COMMSCOPE 2276V VIDEO CABLE RG 6 1000 FEET
$273.90
Product Description
Commscope P/N 2276V
RG6 Foil & Braid Shield Plenum Coax Cable
Quantity: 1x1000FT
SPECIFICATIONS:Construction Materials Construction Type Non-armored Center Conductor Material Copper-clad steel wire Dielectric Material Foam FEP Jacket Material PVC Shield (Braid) Coverage 90 % Shield (Braid) Gauge 34 AWG Shield (Braid) Material Aluminum Shield (Tape) Material Aluminum/Poly, bonded Dimensions Cable Length 305 m | 1000 ft Cable Weight 28.00 lb/kft Diameter Over Center Conductor 1.0236 mm per 1 strand0.0403 in per 1 strand Diameter Over Center Conductor Tolerance ±0.0004 in Diameter Over Dielectric 4.3180 mm | 0.1700 in Diameter Over Jacket 6.020 mm | 0.237 in Diameter Over Jacket Tolerance ±0.006 in Diameter Over Shield (Braid) 5.207 mm | 0.205 in Jacket Thickness 0.381 mm | 0.015 in Jacket Thickness, minimum spot 0.254 mm | 0.010 in Electrical Specifications Capacitance 50.9 pF/m | 15.5 pF/ft Characteristic Impedance 75 ohm Characteristic Impedance Tolerance ±3 ohm Conductor dc Resistance 28.60 ohms/kft Dielectric Strength, conductor to shield 2500 Vdc Jacket Spark Test Voltage 2500 Vac Nominal Velocity of Propagation (NVP) 84 % Shield dc Resistance 6.40 ohms/kft Structural Return Loss 15 dB @ 1000 ¬ 3000 MHz | 20 dB @ 5 ¬ 1000 MHz Structural Return Loss Test Method 100% Swept Tested Environmental Specifications Environmental Space Plenum Flame Test Method CMP Operating Temperature -40 °C to +75 °C (-40 °F to +167 °F) Safety Standard cETL | ETL UL Temperature Rating 75 °C | 167 °F General Specifications Cable Type Series 6 Jacket Color White Product Number 2276V Center Conductor Gauge 18 AWG Center Conductor Type Solid Packaging Type Reel Mechanical Specifications Minimum Bend Radius, loaded 20 times Minimum Bend Radius, unloaded 10 times Electrical Performance Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) 1 MHz 1.25 0.38 10 MHz 2.30 0.70 50 MHz 4.85 1.48 100 MHz 6.59 2.01 200 MHz 9.38 2.86 400 MHz 13.87 4.23 700 MHz 19.55 5.96 900 MHz 22.83 6.96 1000 MHz 24.44 7.45 1200 MHz 27.06 8.25 1450 MHz 30.64 9.34 1800 MHz 35.06 10.69 2200 MHz 37.85 11.54 2500 MHz 38.38 11.70 3000 MHz 42.87 13.07 Regulatory Compliance/Certifications Agency Classification RoHS 2002/95/EC Compliant ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system.
RG6 Foil & Braid Shield Plenum Coax Cable
Quantity: 1x1000FT
SPECIFICATIONS:Construction Materials Construction Type Non-armored Center Conductor Material Copper-clad steel wire Dielectric Material Foam FEP Jacket Material PVC Shield (Braid) Coverage 90 % Shield (Braid) Gauge 34 AWG Shield (Braid) Material Aluminum Shield (Tape) Material Aluminum/Poly, bonded Dimensions Cable Length 305 m | 1000 ft Cable Weight 28.00 lb/kft Diameter Over Center Conductor 1.0236 mm per 1 strand0.0403 in per 1 strand Diameter Over Center Conductor Tolerance ±0.0004 in Diameter Over Dielectric 4.3180 mm | 0.1700 in Diameter Over Jacket 6.020 mm | 0.237 in Diameter Over Jacket Tolerance ±0.006 in Diameter Over Shield (Braid) 5.207 mm | 0.205 in Jacket Thickness 0.381 mm | 0.015 in Jacket Thickness, minimum spot 0.254 mm | 0.010 in Electrical Specifications Capacitance 50.9 pF/m | 15.5 pF/ft Characteristic Impedance 75 ohm Characteristic Impedance Tolerance ±3 ohm Conductor dc Resistance 28.60 ohms/kft Dielectric Strength, conductor to shield 2500 Vdc Jacket Spark Test Voltage 2500 Vac Nominal Velocity of Propagation (NVP) 84 % Shield dc Resistance 6.40 ohms/kft Structural Return Loss 15 dB @ 1000 ¬ 3000 MHz | 20 dB @ 5 ¬ 1000 MHz Structural Return Loss Test Method 100% Swept Tested Environmental Specifications Environmental Space Plenum Flame Test Method CMP Operating Temperature -40 °C to +75 °C (-40 °F to +167 °F) Safety Standard cETL | ETL UL Temperature Rating 75 °C | 167 °F General Specifications Cable Type Series 6 Jacket Color White Product Number 2276V Center Conductor Gauge 18 AWG Center Conductor Type Solid Packaging Type Reel Mechanical Specifications Minimum Bend Radius, loaded 20 times Minimum Bend Radius, unloaded 10 times Electrical Performance Frequency Attenuation (dB/100 m) Attenuation (dB/100 ft) 1 MHz 1.25 0.38 10 MHz 2.30 0.70 50 MHz 4.85 1.48 100 MHz 6.59 2.01 200 MHz 9.38 2.86 400 MHz 13.87 4.23 700 MHz 19.55 5.96 900 MHz 22.83 6.96 1000 MHz 24.44 7.45 1200 MHz 27.06 8.25 1450 MHz 30.64 9.34 1800 MHz 35.06 10.69 2200 MHz 37.85 11.54 2500 MHz 38.38 11.70 3000 MHz 42.87 13.07 Regulatory Compliance/Certifications Agency Classification RoHS 2002/95/EC Compliant ISO 9001:2008 Designed, manufactured and/or distributed under this quality management system.