RG 6 Quad Shield. Surveillance, CATV & MATV, RG-6, 18 AWG solid bare copper, foam FEP core, Duofoil® + 60% aluminum braid + Duofoil® + 40% aluminum braid, Low Smoke PVC jacket, CMP, CATVP .
Suitable Applications
CATV, MATV
Construction Details
RG Type 6
Conductor
18 AWG Solid 0.040 in BC - Bare Copper
Insulation Material
FEP - Fluorinated Ethylene Propylene (Foam) 0.170 in (4.32 mm)
Outer Shield
Layer Outer Shield Type Material Material Trade Name Coverage
1 Tape Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
2 Braid Aluminum 60%
3 Tape Tri-Laminate (Alum+Poly+Alum) Duofoil® 100%
4 Braid Aluminum 40%
Outer Jacket
Material Nom. Diameter
PVC - Polyvinyl Chloride 0.246 in (6.25 mm)
Overall Cable Diameter (Nominal)
0.246 in (6.25 mm)
Electrical Characteristics
Attenuation
Frequency Nom. Attenuation
1 MHz 0.24 dB/100ft
3 MHz 0.45 dB/100ft
5 MHz 0.55 dB/100ft
8 MHz 0.70 dB/100ft
10 MHz 0.85 dB/100ft
50 MHz 1.50 dB/100ft
100 MHz 2.10 dB/100ft
200 MHz 3.10 dB/100ft
400 MHz 4.50 dB/100ft
700 MHz 6.00 dB/100ft
900 MHz 6.90 dB/100ft
1000 MHz 7.30 dB/100ft
Electricals
Nom. Conductor DCR Nom. Outer Shield DCR Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedance Nom. Velocity of Prop.
6.4 Ohm/1000ft (21 Ohm/km) 2.5 Ohm/1000ft (8.2 Ohm/km) 16.3 pF/ft (53.5 pF/m) 75 Ohm 83%
Voltage
UL Voltage Rating
300 V (CMP)
Mechanical Characteristics
Temperature
UL Temperature Operating
75°C -5°C to +75°C
Bend Radius
Installation Min.
2.5 in
Max. Pull Tension
76 lbs (34 kg)
Bulk Cable Weight
31 lbs/1000ft
Standards and Compliance
Environmental Suitability
Indoor - Plenum, Indoor
Sustainability
CA Prop 65, Product Lens™, Environmental Product Declaration (EPD) Available
Flammability / Reaction to Fire
NFPA 262, FT6
NEC / UL Compliance
CATVP, CMP
CEC / C(UL) Compliance
CMP
European Directive Compliance
EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), REACH, EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)